J'ai eu besoin de me connecter sur différents switch HP Procurve en console. Premier problème mon pc n'a pas de port série donc du coups j'ai acheté un adaptateur USB/serie Aten UC-232A.
Première étape connexion de l'adaptateur USB sur le pc :
tailf /var/log/message
Nov 15 10:47:50 pcinf01 kernel: [ 536.175041] usb 6-2: new full-speed USB device number 3 using uhci_hcd
Nov 15 10:47:50 pcinf01 kernel: [ 536.322058] usb 6-2: New USB device found, idVendor=0557, idProduct=2008
Nov 15 10:47:50 pcinf01 kernel: [ 536.322064] usb 6-2: New USB device strings: Mfr=1, Product=2, SerialNumber=0
Nov 15 10:47:50 pcinf01 kernel: [ 536.322068] usb 6-2: Product: USB-Serial Controller D
Nov 15 10:47:50 pcinf01 kernel: [ 536.322071] usb 6-2: Manufacturer: Prolific Technology Inc.
Nov 15 10:47:50 pcinf01 kernel: [ 536.325112] pl2303 6-2:1.0: pl2303 converter detected
Nov 15 10:47:50 pcinf01 kernel: [ 536.337181] usb 6-2: pl2303 converter now attached to ttyUSB0
Nov 15 10:47:50 pcinf01 mtp-probe: checking bus 6, device 3: "/sys/devices/pci0000:00/0000:00:1d.0/usb6/6-2"
Nov 15 10:47:50 pcinf01 mtp-probe: bus: 6, device: 3 was not an MTP device
Le convertisseur est bien reconnu et attaché au périphérique /dev/ttyUSB0. J'ai fais différents essais et ça a marché avec minicom.
En root
minicom -s
- "Configuration du port série"
- A --> /dev/ttyUSB0
- E --> 9600 8N1
- F --> Non
- G --> Non
Appuyer sur échappe pour sortir. Enregistrer la configuration et quitter minicom.
Toujours en root :
minicom -o
Vous êtes sur l'accueil de minicom, pour accéder aux options utiliser la combinaison de touche CTRL-A puis appuyer sur Z. Dans le menu utiliser la touche M pour initialiser la connexion.
Et voila magie vous êtes connecté, c'est pas très rapide mais ça marche.